Features:
High heat input
High turndown ratio
Concentrated sidewall heating
Low volume of combustion Products and reduced volatilisation
Integrated safety features
Benefits:
Improved thermal Homogeneity
Faster responses
Increased glass throughput
Improved glass quality
Longer superstructure refractory life with volatile glasses
Glass Type
Suitable for most glass types
Roof Blocks
Design: 400 series design.
Material: To suit glass type
Glass Contact Blocks
Design: As conventional forehearths
Material: To suit glass type
Burner blocks
Design: Modified forehearth K type burner block
Materials: Special High Alumina
Burner nozzles and manifolds
Nozzle Design: Patented nozzle mix burner
Capacity: 0.3 to 3.6kW (1,000 to 12,000 Btu/hr)
Burner centres: 114mm (4.5 inches) - Standard
Manifold Design: Linked gas and oxygen manifolds on quick withdrawal brackets
Combustion pipework
Gas: Mild steel with threaded joints
Oxygen: Copper with silver soldered joints
Combustion controls
Gas and Oxygen Controls Motorised adjustable port valves
Measuring devices Mass flow meters
Safety Standard To BS EN 746-2: 1997
Process Control
Main Control loops: Zone temperature control
Secondary Control loops: Gas flow, oxygen flow and ratio control
Interlocks Ratio limiting
Service Requirements
Combustion gas: Natural gas
Oxygen: 90% purity or better
Power Supply: 110-240V, single phase, 50-60 Hz
Environment (Panel): -20° C to 60° C (-4° F to 140° F)